900字范文,内容丰富有趣,生活中的好帮手!
900字范文 > 校准器 calibrator英语短句 例句大全

校准器 calibrator英语短句 例句大全

时间:2018-12-11 16:09:29

相关推荐

校准器 calibrator英语短句 例句大全

校准器,calibrator

1)calibrator[英]["k?li,breit?][美]["k?l?,bret?]校准器

1.A Calibrator for Leakage Current Meter;一种漏电流测量仪表校准器

2.Along with the bridges for measuring temperatureand the low electric potential cocurrent potentiometer has beentaken placed by the thermal resistance,thermocouple test instrument or digital multimeter,in order to solve the calibration problem,wedevelop thiscalibrator according to itscharacteristic,and show the uncertainty inmeasurement.随着测温电桥和低电势直流电位差计分别被热电阻、热电偶测试仪或数字多用表所代替,为解决其校准问题,我们根据其特点研制了这套校准器,并给出了测量不确定度。

英文短句/例句

1.Sound calibratorsGB/T15173-1994声校准器

2.amplitude calibration unit振幅校准器振幅测量器

3.slope/temperature factor adjustment of pH meterpH计的斜率/温度系数校准器

4.To calibrate your game controller, click Calibrate.要校准游戏控制器,请单击“校准”。

5.calibration marker校准指示器, 校准标记(频标, 时标)

6.To adjust the line of sight of(an optical device).校准调整光学仪器瞄准器

7.calibrated measuring [volumetric]tank校准测量[容积计量]容器

8.calibrated measuring volumetrictank校准测量/容积计量容器

9.intercalibration (of observational instrumentation)观测仪器的相互校准

10.regulate a clock, radiator, etc校准时钟、 调节散热器

11.picture line-up generating equipment图像校准信号发生器

12.Quasi-δ Function Calibration of Dynamic Characteristic of High-Pressure Transducer;高压传感器准δ动态校准系统的研究

13.Methods for calibration of vibration and shock pick-ups--Primary shock calibration by light cuttingGB/T13823.13-1995振动与冲击传感器的校准方法光切割法冲击校准(一次校准)

14.Makeready: Operations necessary to prepare a machine ready to do a speical job.校机:把机器调校妥当,准备生产的操作.

15.Mathematical Model of a Pistonphone Vsed in Microphone Calibration传声器校准用活塞发生器的数学模型

16.Researches on Quasi-Dynamic Calibration Technique and Experiment with Plastic Pressure-Measuring Elements;塑性测压器材准动态校准技术及实验研究

17.The Meaning and Calibration Methods with High-value Standard Resistor Voltage Coefficient高值标准电阻器电压系数的意义及其校准方法

18.Research of Quasi-static Calibrating Technology for Blast Pressure Sensor爆破压力传感器准静态校准装置应用研究

相关短句/例句

collimator calibration准直器校准

3)reference standard校准器;标准

4)instrument calibration仪器校准

5)weighing instrument calibration衡器校准

1.Necessity and operability of theweighing instrument calibration;衡器校准的必要性和可操作性

6)sound etalon声校准器

1.Sound etalon is an acoustic measurement equipment of great significance according to the National Measurement Calibration Standards——JJG176-95, asound etalon is required to conduct calibration in three indexes, i.声校准器是一种重要的声学计量器具。

延伸阅读

传感器如何进行无源校准及两点特别说明a)首先读出变送器内部设置的4mA压力值和20mA压力值,看是否与实际的4mA压力值和20mA压力值相一致,若一致,则直接更改4mA压力值和20mA压力值到量程迁移后的压力值即可。 b)如果变送器内部设置的4mA压力值和20mA压力值,与实际的4mA压力值和20mA压力值不一致,可先把实际的4mA压力值和20mA压力值折算到变送器内部设置的4mA压力值和20mA压力值,再折算量程迁移后的压力值,将折算值更改到4mA压力值和20mA压力值便可。例如:假设一台变送器量程为-10bar-50bar,想将量程迁移到10bar-40bar,读出变送器内部设置的4mA 压力值和20mA压力假设为0-10Kpa,进行如下折算:-10bar 和0相对应,50bar和10Kpa相对应,通过计算,可以计算出折算方程为:P折=P实/6+10/6("P折"为折算后的压力值,"P实"为实际压力值),由此方程可计算出折算后4mA压力值应为:10/6+10/6=3.333KPa,折算后20mA的压力值应为:40/6+10/6=8.333KPa, 于是可以通过组态软件将变送器内部的4mA压力值设置为3.333,将20mA压力值设置为8.333便可。特别说明: 1)量程迁移只能在原量程范围内迁移,若迁移超出原量程范围,则变送器的线性度变会变差。 2)进行无源校准时,量程迁移不可过大,迁移比最好不要大于3:1,过大会造成变送器输出不稳定,而且分辨率较低。大迁移比量程迁移在要先进行增益设置,再进行输入压力校准。

本内容不代表本网观点和政治立场,如有侵犯你的权益请联系我们处理。
网友评论
网友评论仅供其表达个人看法,并不表明网站立场。